eLibrary
  • Home
  • Sources
  • Search
  • About

Prevention, Detection, and Management of Complications Associated with CT-Guided Ablation of Pulmonary Nodules

Xiaoyu Dong, Feng Xu
World Scientific Research Journal, (2026), Vol.12, No.7, pp.36-43
Published: July 16, 2026
DOI: 10.6911/WSRJ.202607_12(7).0004
PDF: Download Full Text PDF
Abstract

CT-guided ablation delivers precise positioning, minimal trauma, rapid postoperative recovery and repeatable treatment, so it has become a key clinical strategy for pulmonary nodules. As an invasive intervention, this procedure cannot fully eliminate postoperative complications. This review collects domestic and international research papers published in recent years, summarizes four major complications—pneumothorax, pleural effusion, bleeding and pain, and elaborates each complication’s incidence, clinical manifestations, risk factors, management protocols and preventive strategies. The summaries in this paper offer clinical references to reduce the incidence of post-ablation complications and advance CT-guided pulmonary nodule ablation toward standardized, precise and safer clinical workflows.

Keywords: CT-guided Ablation, Pulmonary Nodule, Postoperative Complications.
APA Citation: Xiaoyu Dong, Feng Xu (2026). Prevention, Detection, and Management of Complications Associated with CT-Guided Ablation of Pulmonary Nodules. World Scientific Research Journal, 12(7), 36-43. https://doi.org/10.6911/WSRJ.202607_12(7).0004

References

  1. Pulmonary Nodule Standardized Diagnosis and Treatment Expert Consensus Group. (2024). Expert consensus on standardized diagnosis and treatment of pulmonary nodules. Journal of Tuberculosis and Lung Disease, 5(5), 388–397.
  2. Cardella, J. F., et al. (2003). Society of Interventional Radiology clinical practice guidelines. Journal of Vascular & Interventional Radiology, 20(9).
  3. Wang, Z., Liu, Y., Cao, X., et al. (2024). Risk prediction model for pneumothorax or pleural effusion after microwave ablation in patients with lung malignancy. Heliyon, 10(19), e38422. https://doi.org/10.1016/j.heliyon.2024.e38422
  4. Xin, S., Yang, Y., Gao, F., et al. (2024). Clinical summary of safety and efficacy of CT-guided microwave ablation in 38 cases of lung cancer. Progress in Modern Biomedicine, 24(23), 4444–4448. https://doi.org/10.13241/j.cnki.pmb.2024.23.009
  5. Sun, R. (2024). CT-guided microwave ablation for the treatment of small pulmonary nodules: efficacy analysis and study of influencing factors of complications [Master’s thesis]. Qingdao University.
  6. Yoshimatsu, R., Yamagami, T., Terayama, K., et al. (2008). Delayed and recurrent pneumothorax after radiofrequency ablation of lung tumors. Chest, 135(4), 1002–1009. https://doi.org/10.1378/chest.07-1346
  7. Kashima, M., Yamakado, K., Takaki, H., Kodama, H., Yamada, T., Uraki, J., & Nakatsuka, A. (2011). Complications after 1000 lung radiofrequency ablation sessions in 420 patients: a single center's experiences. AJR American Journal of Roentgenology, 197(4), W576–W580. https://doi.org/10.2214/AJR.11.6408
  8. Yamagami, T., Kato, T., Hirota, T., Yoshimatsu, R., Matsumoto, T., & Nishimura, T. (2006). Pneumothorax as a complication of percutaneous radiofrequency ablation for lung neoplasms. Journal of Vascular and Interventional Radiology, 17(10), 1625–1629. https://doi.org/10.1097/01.RVI.0000236607.05698.4A
  9. Nour-Eldin, N. E., Naguib, N. N., Saeed, A. S., Ackermann, H., Lehnert, T., Korkusuz, H., & Vogl, T. J. (2009). Risk factors involved in the development of pneumothorax during radiofrequency ablation of lung neoplasms. AJR American Journal of Roentgenology, 193(1), W43–W48. https://doi.org/10.2214/AJR.08.1457
  10. Wu, C., Zhao, Y., Chen, M., et al. (2025). Risk factors and nomogram prediction model for pneumothorax after CT-guided coaxial biopsy combined with microwave ablation in ground-glass nodules. Clinics, 80, 100750. https://doi.org/10.1016/j.clin.2025.100750
  11. Zhao, Y., Xue, T., Li, B., et al. (2025). Research advances in ablation therapy for non-small cell lung cancer. Journal of Modern Oncology, 33(7), 1216–1225.
  12. Li, S., Han, Z., Jin, X., et al. (2023). Efficacy and safety of microwave ablation in the treatment of lung cancer. Oncology Progress, 21(17), 1888–1893.
  13. Wang, Z., Liu, Y., Cao, X., et al. (2024). Risk prediction model for pneumothorax or pleural effusion after microwave ablation in patients with lung malignancy. Heliyon, 10(19), e38422. https://doi.org/10.1016/j.heliyon.2024.e38422
  14. Hiraki, T., Tajiri, N., Mimura, H., Yasui, K., Gobara, H., Mukai, T., Hase, S., Fujiwara, H., Iguchi, T., Sano, Y., Shimizu, N., & Kanazawa, S. (2006). Pneumothorax, pleural effusion, and chest tube placement after radiofrequency ablation of lung tumors: incidence and risk factors. Radiology, 241(1), 275–283. https://doi.org/10.1148/radiol.2411050716
  15. Xu, S., Qi, J., Li, B., Bie, Z. X., Li, Y. M., & Li, X. G. (2021). Risk prediction of pleural effusion in lung malignancy patients treated with CT-guided percutaneous microwave ablation: a nomogram and artificial neural network model. International Journal of Hyperthermia, 38(1), 220–228. https://doi.org/10.1080/02656736.2021.1882676
  16. Nour-Eldin, N. E., Naguib, N. N., Mack, M., Abskharon, J. E., & Vogl, T. J. (2011). Pulmonary hemorrhage complicating radiofrequency ablation, from mild hemoptysis to life-threatening pattern. European Radiology, 21(1), 197–204. https://doi.org/10.1007/s00330-010-1901-6
  17. Steinke, K., King, J., Glenn, D., & Morris, D. L. (2003). Pulmonary hemorrhage during percutaneous radiofrequency ablation: a more frequent complication than assumed? Interactive Cardiovascular and Thoracic Surgery, 2(4), 462–465. https://doi.org/10.1016/S1569-9293(03)00083-4
  18. Liang, Z. (2021). Observation on the success rate and early curative effect of CT-guided microwave ablation of lung cancer nodules. Chinese and Foreign Medical Research, 19(10), 168–170.
  19. Liu, X. (2023). Clinical analysis of microwave ablation in the treatment of lung cancer [Master’s thesis]. Dalian Medical University.
  20. Liu, B. D., Chen, H. Q., Liu, L. X., et al. (2023). Chinese expert consensus on multidisciplinary minimally invasive diagnosis and treatment of pulmonary nodules. Chinese Journal of Clinical Thoracic and Cardiovascular Surgery, 30(8), 1061–1074.
  21. Abudurexiti, N., & Wu, C. (2026). Research progress on cryoablation therapy for pulmonary nodules. China Modern Doctor, 64(10), 121–125.
  22. Jiang, B., McClure, M. A., Chen, T., & Chen, S. (2018). Efficacy and safety of thermal ablation of lung malignancies: A network meta-analysis. Annals of Thoracic Medicine, 13(4), 243–250. https://doi.org/10.4103/atm.ATM_144_18
  23. Li, Y., Du, Y., Yang, H. F., Yu, J. H., & Xu, X. X. (2013). CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions. Clinical Radiology, 68(1), e43–e48. https://doi.org/10.1016/j.crad.2012.08.016
  24. Jia, H., Tian, J., Liu, B., Meng, H., Pan, F., & Li, C. (2019). Efficacy and safety of artificial pneumothorax with position adjustment for CT-guided percutaneous transthoracic microwave ablation of small subpleural lung tumors. Thoracic Cancer, 10(8), 1710–1716. https://doi.org/10.1111/tca.12537
  25. Yuan, Z., Juan, C., Qi, D., et al. (2025). A qualitative study of symptom experience in elderly patients with lung cancer after microwave ablation. Geriatrics & Health Care, 31(1), 69–73.
  26. Meng, L. L., Zhang, X., Zhang, X. B., et al. (2025). Research progress on preventing nerve injury and pain management during thermal ablation of lung tumors. Chinese Journal of Interventional Imaging and Therapy, 22(9), 600–603.
  27. Helm, J. M., Swiergosz, A. M., Haeberle, H. S., Karnuta, J. M., Schaffer, J. L., Krebs, V. E., Spitzer, A. I., & Ramkumar, P. N. (2020). Machine learning and artificial intelligence: Definitions, applications, and future directions. Current Reviews in Musculoskeletal Medicine, 13(1), 69–76. https://doi.org/10.1007/s12178-020-09600-8
  28. Okuma, T., Matsuoka, T., Yamamoto, A., Oyama, Y., Toyoshima, M., Nakamura, K., & Inoue, Y. (2008). Frequency and risk factors of various complications after computed tomography-guided radiofrequency ablation of lung tumors. CardioVascular and Interventional Radiology, 31(1), 122–130. https://doi.org/10.1007/s00270-007-9162-1
  29. Wang, L. N., Liu, J., Shi, H. L., et al. (2025). Risk assessment of pain associated with CT-guided lung microwave ablation. Journal of Medical Imaging, 35(2), 55–59.
  30. Thong, I. S. K., Jensen, M. P., Miró, J., & Tan, G. (2018). The validity of pain intensity measures: what do the NRS, VAS, VRS, and FPS-R measure? Scandinavian Journal of Pain, 18(1), 99–107. https://doi.org/10.1515/sjpain-2017-0132
  31. Han, X. J. (2021). Application study of CT-guided artificial pneumothorax technique in microwave ablation of subpleural lung tumors [Master’s thesis]. Shandong University.
  32. Wang, S. B., Chen, Z. N., Guo, X. Y., et al. (2025). Current status of non-invasive thermometry techniques for CT-guided thermal ablation of lung cancer. Chinese Journal of Interventional Imaging and Therapy, 22(7), 486–489.
© 2026 eLibrary · Stand on the shoulders of giants